Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 495
Filtrar
3.
J Cardiothorac Surg ; 19(1): 186, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582866

RESUMO

Coronary artery fistula (CAF) is characterized as a congenital or acquired abnormal communication between a coronary artery and any of the four chambers of the heart (coronary-cameral fistula) or great vessels (coronary arteriovenous fistula) bypassing the capillaries within myocardium. CAF is a rare disease, challenging to diagnose and treat depending on the anatomical location and type of the fistula and accompanying diseases. This study aims to report a case with multiple coronary artery to coronary sinus (CS) fistulas with giant left circumflex artery and multivalvular infective endocarditis.


Assuntos
Fístula Arteriovenosa , Doença da Artéria Coronariana , Seio Coronário , Anomalias dos Vasos Coronários , Endocardite Bacteriana , Endocardite , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Doença da Artéria Coronariana/complicações , Endocardite/complicações , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/cirurgia
4.
J Invasive Cardiol ; 36(3)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38441993

RESUMO

We report the case of a 79-year-old male patient who benefited from the implantation of a coronary sinus reducer (CSR) (Reducer; Neovasc, Inc.) in the management of typical angina with mild exertion with optimal medical treatment.


Assuntos
Seio Coronário , Artéria Pulmonar , Masculino , Humanos , Idoso , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/terapia
5.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38214677

RESUMO

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Angina Estável/diagnóstico , Qualidade de Vida , Seio Coronário/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/terapia
6.
J Cardiovasc Electrophysiol ; 35(4): 856-861, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38297424

RESUMO

INTRODUCTION: With the entry of pulsed-field ablation (PFA) into electrophysiology, new possibilities for ablation of different substrates such as epicardial foci of premature ventricular contractions (PVCs) from coronary venous system (CVS) have been opened. METHODS: This article focuses on a case of a 27-year-old patient with frequent monomorphic PVCs of epicardial origin, treated by radiofrequency ablation, followed by PFA. RESULTS: After unsuccessful focus ablation through CVS with RFA, successful ablations from the same region with PFA were achieved. CONCLUSION: This is the first described case of successful ablation of epicardial PVCs using PFA, which we hope will help in defining indications for this novel technology and enhance quality of treatment for patients with different arrhythmias.


Assuntos
Ablação por Cateter , Seio Coronário , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Adulto , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ventrículos do Coração , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia
7.
Int Heart J ; 65(1): 155-158, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296570

RESUMO

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Assuntos
Seio Coronário , Cardiopatias Congênitas , Comunicação Interatrial , Idoso , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Seio Coronário/anormalidades , Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Síndrome , Tomografia Computadorizada por Raios X
10.
Ann Noninvasive Electrocardiol ; 29(1): e13100, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38115789

RESUMO

BACKGROUND: Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. METHODS AND RESULTS: This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure, and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the conventional method group, two patients experienced complications (one patient with pericardial effusion and the other patient with femoral arterial hematoma), and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the conventional method group were significantly longer than those in the 3D mapping method group. CONCLUSIONS: The utilization of 3D mapping led to reduced fluoroscopy time, shorter procedure duration, enhanced acute success rates, and decreased incidence of complications.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Seio Coronário , Divertículo , Cardiopatias Congênitas , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Estudos Retrospectivos , Eletrocardiografia/métodos , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Cardiopatias Congênitas/cirurgia , Ablação por Cateter/métodos , Divertículo/complicações , Divertículo/diagnóstico por imagem , Divertículo/cirurgia
11.
Curr Probl Cardiol ; 49(1 Pt C): 102200, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37956917

RESUMO

In an adult patient, coronary artery fistula involving the circumflex artery (CX) connected to the coronary sinus caused aneurysm of the left main and CX associated with ectasia of the intermediate branch. The patient had posterolateral infarction with severe ischemic mitral regurgitation and moderate tricuspid regurgitation. A rare venous return anomaly was also present. The inferior vena cava, which was interrupted at the level of the liver, continued with the hemiazygos to drain into a persistent left superior vena cava, which in turn drained into the coronary sinus. Surgery included CX closure and mitral and tricuspid repair. The strategy had to be adapted to the anatomy. The fistula was dissected and snared for cardioplegia delivery, and venous return was achieved by cannulation of the superior vena cava and femoral vein. The procedure was uneventful, and 4 years later the patient is asymptomatic.


Assuntos
Seio Coronário , Fístula , Cardiopatias Congênitas , Humanos , Adulto , Seio Coronário/cirurgia , Veia Cava Superior/anormalidades , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Veia Cava Inferior/cirurgia , Veia Cava Inferior/anormalidades
12.
Ann Cardiol Angeiol (Paris) ; 72(6): 101683, 2023 Dec.
Artigo em Francês | MEDLINE | ID: mdl-37918330

RESUMO

Coronary sinus Reducer implantation is a percutaneous technique used to treat patients suffering from refractory angina pectoris. The device narrows the coronary sinus, increases the back pressure in the myocardial venous system and forces redistribution of coronary blood flow from less ischemic subepicardium to the more ischemic subendocardium. Multiple clinical studies had proven its efficacy to alleviate myocardial ischemia and related symptoms, and to improve the quality of life of patients with refractory symptomatic chronic coronary artery disease for whom coronary revascularization is deemed unsuitable. This literature review aims to expose the device design, its mechanisms of action, and the clinical data supporting its use. Since November 2021 Reducer's reimbursement has been granted in France by the national health authority. It is the first device to be approved under a newly established reimbursement approval process. A transitional coverage is provided with opportunities for renewal before applying for full-time reimbursement. To fulfill the requirements of the National Commission for Evaluation of Medical Devices and Health Technologies, the French Society of Cardiology has been creating the France Reducer registry. This clinical registry has been collecting data from patients undergoing coronary sinus Reducer implantation regarding their clinical situation, periprocedural information, and one-year follow-up. It is crucial for the future of this emerging therapeutic option in France. To date, 215 patients from 28 centers have been included between June 2022 and September 2023.


Assuntos
Seio Coronário , Isquemia Miocárdica , Humanos , Seio Coronário/cirurgia , Qualidade de Vida , Resultado do Tratamento , Isquemia Miocárdica/cirurgia , França , Sistema de Registros
13.
BMC Cardiovasc Disord ; 23(1): 516, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875809

RESUMO

BACKGROUND: The vein of Marshall (VOM) ethanol infusion is increasingly performed in combination with catheter ablation in atrial fibrillation (AF). The cannulation of the VOM can sometimes be challenging. This study aimed to evaluate the double-wire technique in cases of difficult cannulation of the VOM. CASE PRESENTATION: Patients with AF scheduled for combined catheter ablation and VOM ethanol infusion were consecutively enrolled. The procedure was performed via the femoral vein. If the regular cannulation technique with one angioplasty wire failed or took more than 20 min, the double-wire technique using a stabilizing wire and a cannulation wire was performed. The unique technique was used mainly in two scenarios, when the Eustachian ridge was too prominent as a barrier for catheter manipulation or when the VOM ostium was close to the coronary sinus ostium. Of 162 patients scheduled for VOM ethanol infusion, the double-wire technique was applied in 6 (3.7%) patients and led to a 100% successful cannulation rate of the VOM. Of the six patients, two had a prominent Eustachian ridge, and four had a VOM ostium close to the coronary sinus ostium. The mean cannulation time was 33.3 ± 7.3 min. The ethanol infusion was successfully performed in 5 patients. One patient had a collateral circulation in the distal VOM, and ethanol infusion was not performed. CONCLUSIONS: The double-wire technique can facilitate VOM cannulation and ethanol infusion in challenging cases. WORD COUNT: 231.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Seio Coronário , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Cateterismo , Seio Coronário/cirurgia , Vasos Coronários , Etanol/administração & dosagem
14.
J Interv Card Electrophysiol ; 66(9): 2153-2164, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37864653

RESUMO

BACKGROUND: Intracoronary sinus ablations have been performed for various arrhythmical substrates. The aim of this study is to report our experience on pediatric patients of the safety and efficacy of ablations in the coronary sinus. METHODS: This is a retrospective study of all patients who underwent ablations in the coronary sinus from October 2013 to October 2021 at a single center. Clinical presentation, type of arrhythmia causing tachycardia, ablation procedure, and outcome were recorded. RESULTS: A total of 27 patients were included in the study. Nineteen (69%) of those followed up received a diagnosis of Wolff-Parkinson-White syndrome (WPW), 4 (15%) were cases of supraventricular tachycardia with concealed accessory pathway (AP), 2 (8%) were cases of focal atrial tachycardia, and 2 (8%) were cases of permanent junctional reciprocating tachycardia. Negative delta wave was noteworthy especially in lead II in 11/19 (58%) cases and coronary sinus diverticulum was detected in the WPW cases. Of those with manifest AP (19 cases), 15 (79%) had a high-risk AP and the AP in all WPW cases was adenosine unresponsive. Radiofrequency (RF) catheter ablation was performed in 25/27 (93%) cases during the procedure, and 16/25 (64%) of these were irrigated RF catheters. No complications were observed in the follow-up, including coronary artery injury. CONCLUSIONS: Catheter ablation of supraventricular tachyarrhythmias can be accomplished effectively and potentially safely within the coronary sinus. Coronary sinus diverticula should be suspected in patients with manifest posteroseptal APs who have a previous failed ablation and typical electrocardiographic signs.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Seio Coronário , Taquicardia Supraventricular , Síndrome de Wolff-Parkinson-White , Humanos , Criança , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Estudos Retrospectivos , Síndrome de Wolff-Parkinson-White/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Taquicardia/cirurgia , Eletrocardiografia
15.
J Cardiothorac Surg ; 18(1): 264, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37752517

RESUMO

Aberrant origin of coronary artery is a rare congenital anomaly associated with increased risk of myocardial ischemia and sudden death, with the highest risk lesions being those arising from the opposite sinus of Valsalva. We report a case with an aberrant right coronary artery arising superior to the left coronary cusp, with a slit-like ostium, having an inter-arterial and intramural course through the aortic root, that underwent repositioning of the right coronary artery. We believe such cases warrant surgical correction and reimplantation is a safe, effective and reproducible technique.


Assuntos
Doença da Artéria Coronariana , Seio Coronário , Isquemia Miocárdica , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Coração
16.
J Cardiovasc Electrophysiol ; 34(11): 2398-2402, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37727933

RESUMO

INTRODUCTION: Herein, we present a rare case of the successful ablation of an accessory pathway (AP) involving the Marshall Bundle (MB) and coronary sinus musculature (CSM) in a 40-year-old man with Wolff-Parkinson-White syndrome. METHODS AND RESULTS: An orthodromic reciprocating tachycardia (ORT) was inducible with the earliest atrial activation site located at the posterolateral mitral annulus. The local conduction and the cycle length of ORT was prolonged by peri-mitral ablation; however, it failed to block the AP. The atrial insertion of the AP was identified by remapping during ORT at the left atrial ridge, which was away from the mitral annulus, where ablation was successful. Together with the electrophysiological findings in CSM potentials, we conclude that the epicardial MB-CSM connection functioned as the AP in this patient. CONCLUSION: The novel variant form of AP comprised of MB and CSM should be noted. The atrial insertion of the MB may be the target of catheter ablation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Seio Coronário , Taquicardia Reciprocante , Síndrome de Wolff-Parkinson-White , Masculino , Humanos , Adulto , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirurgia , Fascículo Atrioventricular , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Eletrocardiografia
17.
Am J Cardiol ; 204: 77-83, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37541151

RESUMO

Coronary sinus narrowing device (reducer) implantation has emerged as an effective treatment to improve the quality of life and functional capacity in patients suffering from disabling refractory angina. Left ventricle global longitudinal strain (LV-GLS) is a useful tool for early diagnosis of subclinical cardiac injury and an independent predictor for coronary artery disease. We aimed to investigate whether LV-GLS could help predict clinical improvement after coronary sinus reducer implantation. LV-GLS assessments were performed at baseline and 6 months after reducer implantation in consecutive patients treated for refractory angina. Patients were divided into 2 groups based on reduced (<17% absolute value) or preserved baseline LV-GLS. Clinical improvement was defined as an increase of ≥25 m in the 6-minute walk test (6MWT) at follow-up. Overall, 41 patients were included, 31 in the reduced LV-GLS group and 10 in the preserved LV-GLS group. The mean age was 68 ± 8 years, with only 2 female patients (5%). Baseline characteristics did not differ significantly between the 2 groups. Univariable analysis revealed that LV-GLS was the only significant predictor for 6MWT improvement. Baseline preserved LV-GLS reduced the likelihood of 6MWT improvement by 82% (odds ratio 0.18 [0.04 to 0.83], p = 0.029). A significant increase in 6MWT (307 ± 97 m to 343 ± 92 m, p = 0.017) was observed in the reduced LV-GLS group, compared with a decrease in the preserved LV-GLS group (378 ± 86 m to 361 ± 123 m, p = 0.651). In conclusion, reduced LV-GLS may serve as a marker for potential clinical improvement in patients with refractory angina treated with reducer. Larger clinical trials are needed to establish its role.


Assuntos
Seio Coronário , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Seio Coronário/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Qualidade de Vida , Resultado do Tratamento , Angina Pectoris , Função Ventricular Esquerda
18.
J Vet Cardiol ; 48: 1-6, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37269624

RESUMO

A 5-year-old, 7.9 kg castrated male Miniature Dachsund presented with heart enlargement on radiography. The dog was asymptomatic. Echocardiography revealed a tubular structure running along the posterior wall of the left atrium and connecting to the right atrium on the caudal side of the left atrium and annulus, which was presumed to be a dilated coronary sinus. After confirming a shunt between the left atrium and coronary sinus by cardiovascular catheterization, an unroofed coronary sinus was diagnosed. Open-heart surgery using cardiopulmonary bypass was performed through left atriotomy. The defect between the left atrium and the coronary sinus was closed by suturing. The cardiac enlargement improved after surgery. The dog was still alive 1227 days after surgery without clinical signs.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Seio Coronário , Anomalias dos Vasos Coronários , Doenças do Cão , Comunicação Interatrial , Masculino , Cães , Animais , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Veia Cava Superior/cirurgia , Comunicação Interatrial/cirurgia , Comunicação Interatrial/veterinária , Átrios do Coração , Procedimentos Cirúrgicos Cardíacos/veterinária , Anomalias dos Vasos Coronários/veterinária , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...